During the Building and pest inspection at an Ipswich property in the greater Brisbane area the building inspector noted that the top of the overflow relief gully is lower than the surrounding pavers. The Overflow relief gully should be 75mm above the finished ground levels. The pavers had been installed by the home owner after the original construction. The ground levels need to be lowered to below the Overflow Relief Gully (ORG) as required.

 